Open Office Cabling Systems

Consolidation Point

Telecommunications Systems Bulletin TSB75, "Additional Horizontal Cabling Practices for Open Offices" (published by the Telecommunications Industry Association 8/96), defines two styles of horizontal cabling systems specifically geared towards modular furniture and the open office: the consolidation point and the multi-user telecommunications outlet assembly. Both of these cabling system practices are designed to lessen the amount of "re-cabling" involved in modular furniture moves. Below is an illustration of a typical consolidation point application. The consolidation point functions as an interconnect between two sections of the horizontal cabling: the main cabling from the telecommunications closet and shorter distribution cables which serve outlets in the work area. The consolidation point enclosure is typically mounted in the ceiling or under access flooring. When furniture moves are required, only the shorter cables must be reconfigured. Consolidation point modules are available for both optical fiber and twisted-pair cabling.

Multi-User Telecommunications Outlet Assembly

Telecommunications Systems Bulletin TSB75, "Additional Horizontal Cabling Practices for Open Offices" (published by the Telecommunications Industry Association 8/96), defines two styles of horizontal cabling systems specifically geared towards modular furniture and the open office: the consolidation point and the multi-user telecommunications outlet assembly. Both of these cabling system practices are designed to lessen the amount of "re-cabling" involved in modular furniture moves. Below is an illustration of a typical Multi-User Telecommunications Outlet Assembly (MUTOA) application. The MUTOA is meant to be accessible to users and replaces individual work area outlets. TSB75 allows for the use of work area patch cords longer than the 3 meters specified in the 568 standard to accommodate multiple users. Each MUTOA should be labeled with the longest allowable patch cord according to the table below.
LEARN
Data Sheets
Brochures
White Papers
Technical Articles & Article Reprints
Videos - Information
SELL
Presentations
Information Kits
EVALUATE
Testing
SPECIFY
Visio Drawings
Generic Specifications
CAD Drawings
Cut Sheets
BUY
Catalogs
How to Order
INSTALL
Manuals - All
Videos - Installation - All
Instruction Sheets (IS) - All
WARRANTY
General Inquiries
In the USA
Call 800.553.0938
Email
Outside the USA
AMP NETCONNECT Worldwide
NEED HELP? In the USA: Call 800.553.0938 or email us; Outside the USA: AMP NETCONNECT Worldwide
Terms of Use  |  Privacy  |  Trademarks  |  Site Map  |  ©Copyright 2008 Tyco Electronics Corporation